Removing the
seal for the
remote-control
unit connection
socket
(7)
Fig.10
Removing the
potentiometer
and remote-
control unit
connection
- Solder on 5 soldering points (90) for the potentiometer
socket
- Completely remove the solder from the soldering points (90), using a solder
- Carefully detach the potentiometer (29) from the FPA 15 board
- Solder on 4 soldering points (91) for the remote-control unit connection socket
- Completely remove the solder from the soldering points (91), using a solder
- Carefully detach the remote-control unit connection socket (30) from the FPA 15
Fig.11
Fitting the
potentiometer
and remote-
control unit
- Carefully insert the potentiometer (29) into the 5 soldering points (90)
connection
- Solder the potentiometer (29) onto the 5 soldering points (90)
- Insert the remote-control unit connection socket (30) into the 4 soldering points (91)
socket
- Solder the remote-control unit connection socket (30) onto the 4 soldering points (91)
Note! Never use force to detach the potentiometer (29) and the remote-control
unit connection socket (30) from the LCA 15 board. Before any work involving
the soldering iron, always clean the tip of the soldering iron.
absorption strand or suction pump
absorption strand or suction pump
board
(90)
Note! Only use special electronics soldering tin for soldering-on the
potentiometer (29) and the remote-control unit connection socket (30)
- Carefully pull the seal (7) for the
remote-control unit connection socket
out of the front of the housing
(91)
(30)
Fig.12
103
(29)

Werbung