breaker with the electrical device connected, and if the
manifestation of this non-standard operating behaviour
is not remedied in this way, immediately turn it off by
toggling the power switch to the "OFF" position and
identify the cause of this non-standard behaviour. In the
event that the reason for the non-standard operation is
a fault inside the generator, arrange a repair of the gene-
rator at an authorised service centre for the the HERON®
brand.
VII. Turning off
the generator – 
putting out of operation
1. Set the circuit breaker of the generator to the
"OFF" position (lever down).
2. Set the power switch to the "OFF" Position.
3. Disconnect all appliances from the outputs of the
generator.
4. Shut off the fuel supply using the fuel valve by set-
ting the lever to position "0" on the pictogram.
            If it is required to quickly shut off the generator, first of
all set the power switch to the "OFF" position and then
set the circuit breakers to the "OFF" position. Then per-
form all the remaining steps.
ATTENTION
y Closing the fuel supply using the fuel valve is neces-
sary, otherwise petrol could pass through the petrol
lines to the engine's cylinders, namely when trans-
porting or handling the engine, and then it is neces-
sary to have the engine's cylinders cleaned out at
an authorized service centre, for which the right of
a cost-free repair does not apply.
109
VIII. Additional
information for the use
of the generator
CONTENT OF OXYGENOUS
COMPOUNDS IN THE FUEL
            The content of oxygenous compounds in lead-free car
petrol must meet the current requirements of norm
EN 228.
Under no condition prepare the fuel blend yourself but
instead procure it only at a fuel station. Do not modify
the composition of the purchased fuel (excluding the
use of a fuel conditioner). Use only good quality lead-
-free car petrol.
OIL SENSOR AND MONITORING
THE OIL AMOUNT
            The generator is fitted with an oil sensor (fig. 3, positi-
on 2) that shuts off the engine when the oil level falls
below a critical limit, and thus prevents damage to the
engine resulting from insufficient lubrication. The pre-
sence of this sensor does not entitle the operator
to omit regular checks of the amount of oil in the
engine's oil tank.
            The oil sensor must not be removed from the gene-
rator.
DIGITAL METER OF OUTPUT
VOLTAGE, FREQUENCY
AND OPERATION HOURS.
y The generator is equipped with a digital motor hours
counter from the last start (the counter is automatically
reset to zero when the engine is turned off) as well as
a total motor hours counter (symbol "H") from the first
start of the generator, the output voltage (symbol "V")
and frequency (symbol "Hz"), see description of the
front (control) panel of the generator.
It is possible to use the button on the counter to switch
between the individual measured values.
EN