Operation
3. Select
to end the benzene/pre-tube measurement.
4. Remove the pump adapter with the pre-tube if necessary.

4.17 Configuring the device settings

Additional settings can be changed using the Dräger CC-
Vision PC software.
To open the device settings:
1. Select
in measuring mode and confirm the dialog.
2. Sign in with the required user level, if necessary.
3. Select and confirm Settings.

4.17.1 Activating day or night mode

1. Open the device settings.
2. Select and confirm Night mode / Day mode.

4.17.2 Changing the device language

1. Open the device settings.
2. Select Language.
3. Select and confirm the desired language.

4.17.3 Setting date and time

1. Open the device settings.
2. Select Date & time.
3. Select Set date format and then select and confirm the
date format.
4. Select Set date and then set and confirm the date.
5. Select Set time and then set and confirm the time.
The user must manually switch between summer and
winter time.
When using the X-dock maintenance station, automatic
time synchronisation is possible.

4.17.4 Activating silent mode

Silent mode can be activated for 15 minutes on the gas
detector. When silent mode is active, vibration and the horn
are deactivated. Permanent deactivation is possible using the
Dräger CC-Vision PC software.
The technical suitability test expires if the silent mode is
permanently activated.
4.17.5 Activating or deactivating the capture
range
1. Open the device settings.
2. Select Capture ranges.
3. Activate or deactivate the capture range.
4. To adopt the new setting, turn the gas detector off and
back on.
Dräger recommends that you activate the capture ranges
feature.
44
4.17.6 Activating or deactivating Bluetooth
am 8000 only)
1. Open the device settings.
2. Select Bluetooth.
3. Activate or deactivate Bluetooth

4.18 Activating full-range mode

Full-range mode is not part of the technical suitability test.
WARNING
Risk of explosion!
Only for CatEx sensors: The full-range modeonly applies for
methane in the air. Any other gas composition has an impact
on the measured signal, may cause an incorrect display of the
results and may cause permanent damage to the sensor.
► Only use the full-range mode to measure methane in the
air.
The full-range mode can only be activated for the sensors
DrägerSensor CatEx 125 PR (order number 68 12 950) and
CatEx 125 PR Gas (order number 68 13 080) with the
measurement gas methane.
When the full-range mode is activated, the device
automatically switches to the vol. % range if the 100 %LEL
methane range is exceeded.
When the "No measured values in Vol% range" is activated,
the over range in %LEL continues to be displayed instead of
the measured values in the Vol% range.
When the values return to the <100 %LEL methane range,
the measured value display alternates with the transitional
phase indicator (circle arrow).
Prerequisite:
– The measuring ranges %LEL (heat of reaction) and vol. %
(thermal conductions) are calibrated.
1. Activate full-range mode with the Dräger CC-Vision PC
software.
2. If necessary, activate the "No measured values in Vol%
range" using the Dräger CC-Vision PC software.
4.19 Hydrogen (H
2
IR Ex)
The H
added signal can be adjusted using the Dräger CC-
2
Vision PC software.
Requirements:
– At least one DrägerSensor XXS H
activated. H
is set as the measurement gas.
2
– An Ex channel on the DrägerSensor DUAL IR Ex/CO
(68 11 960) or DrägerSensor IR Ex (68 12 180) is
activated.
– Both channels are set to the unit %LEL/%LEL/%LIE.
– The H
added signal is only possible with a DrägerSensor
2
XXS H
HC and an IR Ex channel.