Operation
4.3.3 Visual operation signal with activated D-
Light
An activated D-Light feature allows the user to also check and
indicate compliance with certain settings:
– Evaluation of bump test intervals activated and complied
with (factory setting) or evaluation of the calibration
intervals active and complied with
– Usage interval complied with
The D-Light feature can be activated using the Dräger CC-
Vision PC software.
Signalling visually corresponds to the operating signal.
If one of the conditions listed is not fulfilled and the D-Light is
activated, the greed LED will switch on briefly at regular
intervals (short flash approx. every 60 s) instead of pulsing
periodically.
When transmitting device information via Bluetooth
alarm is disconnected from the evaluation of the D-Light
status.
4.4

Switch the gas detector on or off

4.4.1 Initial start-up

When the gas detector is switched on for the first time, a
wizard starts. The wizard guides the user through the set-up
of the gas detector:
– Language selection, if applicable
– Data format and date
– Time
Then carry out an initial calibration. For further information
see: "Calibrate the gas detector", page 47.

4.4.2 Switching on the gas detector

1. Hold down the OK button for approx. 3 s.
 The display shows a countdown.
 The switch-on sequence and the warm-up phase of
the sensors start.
The following display appear one after the other:
– Start screen
– Firmware version
– Display test (the display alternates between black and
white)
– Alarm element test (LEDs, alarm signal and vibration
alarm)
– Customer-specific information screen (optional and
configurable with the Dräger CC-Vision PC software)
– Alarm thresholds, STEL, TWA (if configured) and LEL
factor (if available)
– Any expired bump test or calibration interval as well as
early warnings (if configured)
– Measured value display
The remaining sensor warm-up time is displayed in the upper,
left-hand corner in a yellow box.
36
WARNING
Incorrect device feature/settings!
Incorrect device features/settings may result in danger to life
and/or risk of explosion.
► Before every use, check whether the display elements, the
alarm features and information are displayed correctly. If
one of the items listed above does not feature correctly or
is incorrect, do not use the gas detector and have it
inspected.
The following features are active during the sensor warm-up
phase:
– The measured values flash
– The yellow LED is illuminated
– A warning notice is displayed
 The gas detector is ready to measure when the measured
values no longer flash and the yellow LED is no longer
®
the gas
illuminated. The warning notice may continue to be
displayed if warnings are pending. For further information
see: "Opening information", page 39.
No alarms are issued during the warm-up phase!

4.4.3 Switching off the gas detector

1. Hold down ▲ and ▼ simultaneously until the displayed
countdown expires.
 The visual, acoustic and vibration alarms activate
briefly.
 The gas detector is switched off.
Or
1. Select
2. Select and confirm Switch off.
The gas detector may only be switched off without a prior
sign-on if the Switch-off allowed feature is activated using
the Dräger CC-Vision PC software. Factory setting: activated
The gas detector switches off automatically when it is
placed in the charging cradle (factory setting). As an option,
this setting can be deactivated using the Dräger CC-Vision
PC software.
If the gas detector remains off for longer than 21 days and
is not charged, deep sleep mode is activated. In deep sleep
mode, the gas detector can no longer be switched on using
the Dräger CC-Vision PC software or the Dräger X-dock. In
this case, the gas detector must be switched on manually. The
sensors then go through their warm-up phase.
4.5

Log user in or out

The gas detector has four configurable user levels. The user
levels can be set using the Dräger CC-Vision PC software.
User level 0 means that the user is not signed on. User levels
1 to 3 require a password for sign-on.
The following passwords are created by default:
User level 1:
in measuring mode and confirm the dialog.
0001
Instructions for use
®
|
X-am
8000