Step 1:
Plug Power cord in and turn switch ON. Connect probes
to L and N on control board. Turn meter to AC Volts.
Control board
Power cord
Step 2:
Plug power cord in and turn switch ON. Connect Probes
to ON/OFF switch. Turn meter to AC Volts.
brown
brown
blue
Original instruction
blue
brown
Control board
Step 3:
Check motor thermal switch. Unplug yellow wires. Meter
should read continuity.
NOTE: Motor should be cool during reading.
Yellow Thermistor
Wires to motor
Step 4:
Disconnect potentiometer. Plug power cord in and turn
switch ON.