5. To flush drain tube and pump turn prime valve down.
6. Turn pressure control to QuickFlush operate until the
pump runs steady and flushing fluid appears in the waste
pail.
QuickFlush Hose and Gun
7. To flush airless hose and spray gun, turn prime valve
horizontal.
8. Hold gun against waste pail. Disengage trigger lock.
Trigger gun and turn pressure control to Quick Flush ope-
rate until the pump runs steady and flushing fluid appears.
9. Stop triggering gun.
10. Raise fluid intake above flushing fluid.
11. With prime valve horizontal. Trigger gun into flushing
pail to purge fluid from hose.
Original instruction
12. Engage trigger lock.
13. Turn pressure control knob to OFF and turn ON/OFF
switch to OFF position. Disconnect power to sprayer.
14. Remove filter from gun and sprayer if installed. Clean
and inspect. Install filter. See separate gun manual.
15. If flushing with water, flush again with mineral spirits
or CoroCheck to leave a protective coating to prevent free-
zing or corrosion.
16. Wipe sprayer, hose and gun with a rag soaked in
water or mineral spirits.