Electrical Installation

19.1

Connecting the boundary cable to the base station

1. Remove the insulation from the boundary cable (2) after laying the cable and connect to the spring ter-
minals (1).
19.2

Connecting the low-voltage cables to the transformer

1
2
3
1. Strip 10 mm of insulation off the low-voltage cables (3 / 4).
2. Unscrew the screws with a screwdriver (2) and connect the low-voltage cables to the transformer (1).
The cables can be connected to either terminal, there is no need to observe a particular polarity.
3. Insert the mains plug of the transformer into the mains socket.