The electrical connection must have interposed an automatic switch which has an
adequate range . It must not have less than 3 mms between the contacts.It is
compulsory to connect the earthwire and it must not be interrupted.
The current feeding of the oven must have a tolerance of +/- 10 %
The electrical chart of the oven is shown at Cap. 11 (Page. 36).
AT THE END OF THE OPERATION, THE AUTHORISED TECHNICIAN
MUST ISSUE A WRITTEN DECLARATION THAT CONFIRMS THE
CONTINUITY OF THE PROTECTION CIRCUIT MEASUREMENTS.
5.3– GAS CONNECTION
The oven is provided with a G 3/4" threaded for the connection to the gas supply.It is
placed at the back side of the oven (FIG.6). The gas connection of the oven to the
gas supply bust be visible and metallic steel or copper tubes should be used.
The oven is provided with a G 3/4" threaded for the connection
to the gas supply.It is placed at the back side of the oven
(FIG.6). The gas connection of the oven to the gas supply bust
be visible and metallic steel or copper tubes should be used.
DURING THE OVEN INSTALLATION IT IS ADVISABLE TO FIT AN
APPROVED GAS TAP TO ISOLATE THE SUPPLY FROM THE
APPLIANCE FOR THE CONVENIENCE OF ANY SUBSEQUENT
REMOVAL OR SERVICING.
Metallic 3 pieces pipe-fitting should be used in the connection between the gas tube
of the oven and the gas supply. Put suitable packings between the pipe-fittings to
ensure tight close joints.
THE OVEN MUST BE FED WITH THE TYPE OF THE GAS OF WHICH
THE APPLIANCE IS DESIGNED (SEE MANE-PALTE CE-FIG.1) AND
THE CHATACTERISTICS SHOULD BE AS SHOWN IN THE
RESPECTIVE TAB. 1-2-3 IN ACCORDANCE TO THE MODEL
INSTALLATION