ELECTRIC CONNECTION

THE
ELECTRIC
COMPULSORILY
TECHNICIAN (ELECTRICIAN) SATISFYING THE TECHNICAL AND PROFESSIONAL
REQUIREMENTS STATED BY THE REGULATIONS IN FORCE IN THE COUNTRY OF
USE OF THE OVEN, WHO MUST ISSUE A DECLARATION OF CONFORMITY FOR
THE INTERVENTION PERFORMED.
FOR DIRECT CONNECTION TO THE NETWORK, YOU MUST HAVE A DEVICE THAT
HAS A CONTACT GAP TO ENSURE THE COMPLETE DISCONNECTION, IN THE
CONDITIONS OF OVERVOLTAGE CATEGORY III, IN ACCORDANCE WITH THE
RULES FOR INSTALLATION.
To connect the machine to the electric network it is necessary to proceed as follows:
1)
connect to the wires to the terminals L1—L2—L3—N —
mm² unsheathed with ferule;
2)
put together the other end of the cable and a plug, which is normalised and polarised (the
distinction between phase and neutral must be unequivocal.
3)
to connect the oven to 230 V single phase is sufficient to make a bridge between L1-L2-L3 with
the special plates present in the terminal box
ONCE THE ELECTRIC CONNECTION HAS BEEN PERFORMED, THE AUTHORIZED
TECHNICIAN (ELECTRICIAN) MUST ISSUE A DECLARATION CERTIFYING THE
MEASUREMENT OF THE CONTINUITY OF THE
CIRCUIT.
THE APPLIANCE IS TO BE SUPPLIED THROUGH A RESIBASIC CURRENT DEVICE
(RCD) HAVING A RATED RESIBASIC OPERATING CURRENT NOT EXCEEDING 30
MA
8
CONNECTION
OF
AND
EXCLUSIVELY
L1
Clamp N.1
L2
Clamp N.2
L3
Clamp N. 3
N
Clamp N. 4 or N. 5
Clamp N. 6
THE
OVEN
TO
THE
PERFORMED
of power cord type H07RNF 3G X "x"
EQUIPOTENTIAL PROTECTION
MAINS
MUST
BY
AN
AUTHORIZED
BE