Electrical connection

Insufficient emergency–stop/emergency-halt facilities
Reduction of personal/plant safety!
"
Emergency–stop/emergency-halt facilities must be active and wi­
thin reach in all system modes.
"
Please note EN 62135-1 and EN 60204-1.
Releasing an emergency–stop/emergency-halt facility must not
"
result in an uncontrolled restart of the system.
"
Make sure that moving system elements are halted safely before
accessing the danger area of the system!
"
Check the proper functioning of the emergency-stop/emergency-
halt circuit prior to start-up.
Inappropriate or missing evaluation of error messages
Possibility of reduction of personal/plant safety, function disturban­
ces!
Many messages can be configured freely in the WT depending on
"
your requirements, either as"warning" (no inhibition) or "error "
(with inhibition).
However, messages with error characteristic always have to be
configured as "error" and thus lead to inhibition of the connected
timer!
Use the available message signals to design the process of your
"
application as safely as possible.
The timer provides a large variety of message signals to feed in
error signals from the process and output errors to the process
(PLC, robot) (e.g. via discrete and/or serial inputs/outputs).
"
Wit respect to fault analysis, please also refer to the information in
Section „Troubleshooting".