200 / 256
Bosch Rexroth AG
Assembly
7.2
Electrical connection of the product
7.2.1
Interference suppression
+
Diode, suitable for small DC voltage
DIODE AND ZENER DIODE
+
DI-ZD attenuation element for large DC voltage con
tactors and defined dropout times
Fig. 22: Noise suppression examples
"
Please note the safety instructions relevant for electrical connection
in Section 2.6.4 starting on page 143 and in Sect. 3.3 starting on
page 151.
"
Make sure that all respective plant sections are deenergized before
and during the electrical connection work.
"
Make sure that the required conditions for electrical connection are
complied with. Refer to Section 15 starting on page 229.
Noise is caused by switching peaks and can interfere with the timer di
rectly or through coupling with connecting lines. Therefore, measures
must be taken to suppress noise.
Eliminate all noise at its very source. Where this is not possible, the
"
noise suppression elements must be attached as close as possible
to the source of noise.
"
First make sure that proper noise suppression is available for all
components containing inductive elements or switchgear.
"
Noise suppression equipment must be installed resistant to fracture
because strong vibration may occur on machines.
DIODE
GND
relays
GND
The following table serves as an example only. The rating of the ne
cessary components depends on the actual load situation.
Table 23:
Rating of noise suppression equipment
24 V
DC
48 V
DC
110 V
220 Ohm / 1 W
AC
220 V
220 Ohm / 5 W
AC
440 V
220 Ohm / 5 W
AC
Simulator PRC7000 |
RC ELEMENT
∼
RC element for AC voltage relays and
AC motors
RC ELEMENT
RC element for spark quenching with
inductive load
Resistor
Capacitor
-
-
-
-
0.5 uF 400/600 V
0.1 uF 500 V
0.1 uF 1000 V
R911344640 / 01
MP
Diode
1 N 5060/ZL 12
1 N 5060/ZL 22