Bosch Rexroth AG
Assembly
7.2.5

Analog output of the electrode force (XGM3, output)

For information on whether the function is available in your unit,
please refer to the type-specific instructions.
Connection:
to XGM3; 10-pole,
2-row.
Mating connector is comprised in the delivery.
Cable length:
max. 50 m at 0.5 mm
max. 100 m at 0.75 mm
Cable type:
shielded
An analog output signal is available at XGM3, pin 1, which can be used
to drive a force generating component.
How the actuating variable is converted into electrode force is
dependent on the actuators used.
The „force calibration" function and/or "conversion factor " (characte­
ristic slope) and "zero shift" (Y characteristic shift) parameters are
available for adjustment.
The output signal at XGM3 is normally output immediately after
selection of a welding task, rather than after its start. For deviations
from this, please refer to the type-specific instructions.
PRC7000
Pressure control
GND
Shield

Fig. 25: Analog output of the force actuating variable

Simulator PRC7000 |
2
2
XGM3
1
to force generating
actuators
2
3
D
R911344640 / 01