Commissioning

Switching on the Simulator PRC7000
Prerequisite for commissioning is the proper installation and function
• of all Emergency-Stop/Emergency-Halt devices
• of the electrical connection including all required sensors
Make sure that the above mentioned prerequisites for commis­
"
sioning are met.
Switch on the 24 V supply.
1.
The display in the diagnosis module should be on „PRC7000" after
booting of the WT or at least display a sequence of numbers.
Connect a programming terminal with installed PRI7000 software
2.
(for connection of programming terminal: refer to Section 7.2.2 from
page 201).
The matching data have to be configured in the timer reference of
the PRI7000 for a successful connection setup.
Check whether the I/O signals for communication with robots, PLC
3.
or control panel are output/imported properly.
Check the proper programming of the welding tasks used (e.g. weld
4.
times, %I (heat), etc.).
Switch on the power supply of the inverter with switch „Netz EIN"
5.
(Power ON), if you have not already done so.
The inverter starts. After approx. 10 seconds the DC link is loaded to
full voltage.
The H2 Status Power Unit LED at the front side of the timer now has
to be lit green.
Check all emergency-stop equipment for correct function.
6.
Test the plant functionality installed for any faults.
7.
We do not accept any liability for damage resulting from the execu­
tion of a program, an individual program block or the manual move­
ment of the handling units.
We furthermore accept no liability for consequential damages which
could have been avoided by programming the PLC appropriately.