Simulator PRC7000
5.2.2.5

XGM3 Force Interface

Function
Force output
(analog)
Force input
(analog)
Operate/Reset
output
(digital)
Sensor supply
Pin
1
2
3
4
5

Fig. 7:XGM3 plug for pressure signals 10-pole, 2-row

Table 13:
Allocation XGM3 plug 10-pole
Pin
Signal name
1
KRAFT_OUT
2
KRAFT_OUT_0V
shield
3
6
KRAFT_IN_1
7
KRAFT_IN_2
8
shield
9
KRAFT_RST
4
shield
5
KRAFT_24V
10
KRAFT_0V
Connection refer to
Bosch Rexroth AG
Information on this product
Pin
6
7
8
9
10
Input/output
output
output
input
input
+24V output
output
output
Tab. 9 Conductors suitable for connection
171 / 256
Specification
Vout (0...+10V)
0V non-floating
Difference input
+-10V
Input resistance
10kOhm
Dig. 24V output
Force sensor supply
from
XDS1/P24VEXT