Herunterladen Inhalt Inhalt Diese Seite drucken

Diagnosis Module; Fig. 17: Diagnosis Module: Front Panel View - Bosch Rexroth Simulator PRC 7000 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Rexroth Simulator PRC 7000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

188 / 256
Bosch Rexroth AG
Information on this product
5.2.3.3

Diagnosis module

Effect of control keys
Automatic displays
Displaying more information
Only in combination with PRC7000.
Esc

Fig. 17: Diagnosis module: Front panel view

Functions:
• Display of the PRC7000 status
• Display and set of the network configuration
• Display and reset faults / warnings
• Trigger "PRC7000 Reset" (timer will be rebooted)
Esc
Return to previous display / level.
Y
(Up)
Move up within a menu.
B
(Down) Move down within a menu.
Enter
Acknowledge - or - call up the next display / level.
Y
B
The
and
keys both have an autorepeat function. If these keys
are pressed down for more than one second, the autorepeat function
is activated.
Booting:
the PRC7000 simulator is currently booting
PRC7000: the PRC7000 simulator is in "Ready" state (normal state)
PRC7000
<xxxxx>: a fault or warning is present.
<xxxxx> represents the fault or warning code.
The fault must be eliminated and reset in order to return the
timer to "Ready" state.
Hardware faults cannot be reset.
Self-acknowledging faults are automatically reset by the system
when the cause of the fault is no longer present (e.g. line voltage off/
on).
For code numbers with explanations and possible remedies, refer to
the PRI7000 online help, Section „Messages".
When the timer has booted (Booting is displayed), it is in "Ready" state
(PRC7000 is displayed) or in a fault state (display of fault number).
Simulator PRC7000 |
8-digit display
B
Y
Enter
R911344640 / 01

Werbung

Kapitel

Inhaltsverzeichnis
loading