Information on this product
• Automatic reweld if current was too low
• Behavior with welding process errors
- automatic reweld (configurable)
- signaling of error/warning can be configured
• Gun management:
- Management of all applicated guns (number dependent on type
of timer)
- stepper function for %I (%I stepping)
- electrode tip dressing including initial dressing
- stepper function for pressure (electrode force stepping)
- warning table with graphic representation of electrode wear
• Generating the gun force:
- Programming the force profile for each sequence block
- Output as analog (voltage, current) and/or digital actuating vari
able (depending on timer type)
- Analog or digital feedback (depending on timer type)
- Force calibration for adjustment of the actuating variable to the
actuators used
• Servo gun:
- optional connection
• Tip dress management:
- management of all tip dressers used
- monitoring tip dress cutter wear
- warning table with graphical representation of tip dress cutter
wear
• Calibration:
- for current (to adjust the welding equipment to an external refer
ence ammeter)
- for force (to adjust the electrode force to an external reference
force meter)
• Logging functions (ISO 9000):
- Fault/event log with weld fault protocol
- Data change protocol
- Welding current log
- Electrode- and tip dress cutter change protocol
• integrated diagnosis memory
• Fault allocation:
- certain process errors/faults can be programmed as "faults" or
"warnings"
• Status display of I/O signals in user interface PRI7000
• %I correction:
- electrode-specific input
• General overview in the network overview
• Timer-related overview based on different filter criteria
• Backup/Auto-Backup (data backup)
• Restore (data retrieval)
• Copying welding tasks