Herunterladen Inhalt Inhalt Diese Seite drucken

Measuring Input For Secondary Voltage Measurement (Xgm1); Fig. 30: With Simulator Prc7000: Connection For Secondary Voltage Measurement - Bosch Rexroth Simulator PRC 7000 Betriebsanleitung

Vorschau ausblenden Andere Handbücher für Rexroth Simulator PRC 7000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

210 / 256
Bosch Rexroth AG
Assembly
7.2.9

Measuring input for secondary voltage measurement (XGM1)

In connection with Simulator PRC7000
This function is only available if the "UI Regulation" option has been
activated,
Connection:
to XGM1
(refer to page 190);
12-pole,
2-row.
Mating connector is comprised in the delivery.
Cable length:
max. 100 m (with recommended cable type)
Cable type:
shielded, core area min. 0.75 mm
XGM1
7
Voltage input
8
Voltage input
9
Shield
Fig. 30: With Simulator PRC7000: Connection for secondary voltage mea­
surement
Simulator PRC7000 |
D
Secondary circuit
R911344640 / 01
2