Connection outside European Union:
The P4 may only be connected to mains supply systems according to this drawing:
2 conductor
1 phase
3 conductor
1 phase
4 conductor
3 phase

4.2 Connection to mains

Connected load: Voltage 100-240 Volts, frequence 50 - 60 Hz, power max. 430 VA. Connect the
fixture to a proper installed grounded system only. If any doubts on the electrical installations
occur, consult a qualified electrician. In case of damages occuring due to a not proper installed
electrical system, warranty claims will be invalidated. Don´t use fixtures when top cover is not
fixed properly. Contact with electronic parts can result in risk for life. (Electrical shock 100-240 V)
Connect fixture only after assuring that the electrical installation fits your demands. If any doubts
occur consult a qualified technician!
WARNING: P4 might light up immediately if standalone mode is active or DMX signal
!
is connected!

4.3 Relaying power to other fixtures

!
WARNING: To ensure propper installation of the plug consult a qualified technican!
Power can be relayed to another device via the grey PowerCon throughput socket that accepts
a grey PowerCon NAC3FCB cable connector. Note that blue input and grey throughput connec-
tors have different design: one type cannot be connected to the other. The value of P4 in chain
depends on the local power network. Never use more than eight (if you have 230V/16A) in one
line. Power throughput cable must be rated 20A minimum, have three conductors 1,5mm² mi-
nimum conductor size and a outer cable diameter of 5-15mm. Use only original PowerCon plug
from Neutrik. See installation manual from manufacturer (www.neutrik.com).
Color
Function
brown
live
blue
neutral
green/yellow
ground
P4
mains
L
L
N
N
PE
L
L
N
PE
L
N
L
L
1
L
N
2
L
3
N
PE
Symbol
„L"
„N"
„PE"
WARNING: P4 only can be used
!
in Canadian mains supply sys-
tem with 2 conductor, 1 phase
with max. 120V!
P4
- 37 -