3.2 Set to factory default

To set back the VS P3 to factory setting press key "Menu" one time.
FACTORY DEFAULT
menu. Select
DEFAULT
displayed. Confirm by pressing key "Enter" again. The personal setting of the
VS P3 will be set back to factory default.

3.3 DMX Addressing

Enter DMX address by means of the keys "+" and "-". Confirm an store by pressing
key "Enter".

3.4 Standalone mode

A sequence consisting of preprogrammed cues can be recalled by means of the
Standalone mode. The sequence will run as a loop. Cues can be entered in two
different ways.
The first way is to program every feature by means of the key of the units own
control panel. The second way is to program the cues by means of a connected
DMX control console and to store them on-board of the VS P3.
Enter DMX values by means of the control panels keys:
Recall standalone mode:
Press key "Menu", then press key "+" five times (s. page 24)
will be displayed. Confirm by pressing "Enter",
again with "Enter". After this the display will show:
Menue by pressing "Enter".
The Modify menu enables access to all parameters of the unit. Use key "+" and "-"
to recall the desired parameter. Confirm choice by pressing "Enter". Enter DMX
values by means of the keys "+" and "-". Store DMX values by pressing key "Enter".
To escape press key "Menu".
Add one step to the sequence:
Press key "+" untill menu
will be displayed. Confirm by pressing key "Enter" again.
SURE?
A new step will be added to the sequence.
The DMX values of the last step will be automatically copied to the new step.
To older DMX values enter Modify menu and proceed like describe in chapter:
Enter DMX values by means of the control panels keys.
Delete one step of a sequence:
Recall the Standalone menue.
Confirm by pressing key "Enter".
to recall the desired steps. Confirm selection by pressing "Enter". Select menue
with "+". Confirm the selection of the step by pressing "Enter".
DELETE
be displayed. Now confirm again by pressing "Enter". The selected step will be deleted.
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Telefon +49 (0)7304-9617-0
will be displayed. Press key "Enter" to enter
LOAD DEFAULTS
is shown. Confirm by pressing key "Enter".
INSERT
STANDALONE STEPS
STEP NR: 1/X
and press key "Enter".
STANDALONE STEPS
will be shown. Confirm
STEP NR. 1/1
. Now recall Modify
MODIFY 1/1
must be shown on the display.
will be displayed. Use keys "+" and "-"
FACTURY
will be
SURE
will
SURE?