Herunterladen Inhalt Inhalt Diese Seite drucken

Control Channel; Gobo Channels; Beam Shape Channel; Service - JB-Lighting P4 Bedienungsanleitung

Hohe leuchtdichte durch sehr kurzen lichtbogen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.1 Control channel

With this channel you can control either the lamp on/off function and also you can perform a
general reset of the fixture (see DMX chart on page 48).
DMX 232-239 for min. 2 seconds switches the lamp off
DMX 240-247 for min. 2 seconds performs a reset of the fixture
DMX 248-255 for min. 2 seconds switches the lamp on
After this DMX commands please set back this channel to the „safe" mode (DMX 000)

6.2 Gobo channels

There are some special functions regarding the gobo channels priority.
First of all if gobo wheel 1 (fixed gobo wheel) is set to DMX 000 and the gobo wheel 2 (rotating
gobo wheel ) is also set to DMX 000 the light output is bounded by the aperture of 6 mm to have
the brightest and strongest light output! (beam mode). To switch to the „gobo mode" keep the
DMX value of gobo 1 at DMX 000 and set the DMX value of gobo 2 to DMX 004 - DMX 255.
There is a third special function, if DMX value for gobo 1 is set to DMX 008 - DMX 255 and gobo
2 is set to a DMX value for a gobo (004-255), you will see the gobo wheel 2 behind gobo wheel
1. Details see also on page 50.

6.3 Beam shape channel

Three different possibilities are available (Details see also on page 48).
DMX 000-007 -> frost
it's always selectable, if you use a glas gobo, the fixture switches automatically to frost or lense,
the beam becomes much more homogeneous than using the lense
DMX 008-015 -> lense
it's always selectable, if you use a glas gobo, the fixture switches automatically to frost or lense,
the beam becomes much more brighter than using the frost.
DMX 016-023 -> open
this option is only selecable if you are using no gobo or if you are using gobo 2. This is the best
option for the beam mode.

7. Service

7.1 Service menu

RESET FIXTURE
This menu offers the command to reset the P4 and can be used as a first remedy if an error
occurs.
ERROR LIST
The ERROR LIST command displays a list of any errors detected. An error can simply be a
harmless and isolated incident, but if repeated errors occur, the P4 may require service or repair.
FUNCTION TEST
This menu provides a general test of all effects. It allows testing without controller. The
re-positioning of pan/tilt is disabled.
LAMP ON
This menu option switches on the lamp of the fixture.
LAMP OFF
This menu option switches off the lamp of the fixture.
P4
- 53 -

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis