3.5 Access control system transponder set

3
Prerequisites for installation
• The processing of the transponder signal is an integral part of the external
control unit.
• The external control unit should preferably be housed in a 65 mm deep flush-
type box (on the inside) (see Installing the external control unit).
• If no switch or button is used beside the door, will have to provide a flush-
type box with a filler panel for the control unit.
• The transponder antenna is located in a box in exposed installation and is to
be installed at the outside of the door.
• Do not install the antenna directly on metal as its range could be decreased
drastically.
• Do not install any other antenna within a radius of 1 m!
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49  369  3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMotion
DANGER! Generally assemble and install always only with the
power off!
Notice: If the external control unit and buttons are placed in the
flush-type box at the same time, they must have a depth of
65 mm!
DANGER! For safety reasons, you are not permitted to install it
in a flush-type box with a 230 V AC switch or socket outlet.
Notice: If plan to installations on a metal substructure, will have
to use a timber board and spacer bolts, if applicable, or large
bore holes to ensure the proper function of the antenna! To test
the scanning performance, may have to tentatively install it
onsite, if applicable.