Operation

Bosch Rexroth AG, MIT: Liftgate, 3 842 358 734/2015-01
9 Operation
Hot surfaces of the electric motors in operation!
Burns can result from the > 65 °C surfaces.
Provide for appropriate guard devices.
Let the unit cool down at least 30 minutes before performing maintenance
and/or repair work.
Unforeseen movement, falling Liftgate
Injuries due to falling Liftgate.
Guide the Liftgate by the handles throughout the entire opening or closing
process.

9.1 Notices regarding operation

Please note:
• The lock is mounted on the upstream side.
• The lock snaps automatically in place.
• To release the lock you need a helper or a pneumatic release, depending on the
system width.

10 Maintenance and repair

High electrical voltage!
Risk of serious injury and even death from electrical shock.
Disconnect the relevant system component before you perform maintenance
and repair work.
Secure the system against unintentional restarting.
High pneumatic pressure!
Risk of serious injury and even death.
Disconnect the relevant system component from the pneumatic pressure
source before you perform maintenance and repair work.
Secure the system against unintentional restarting.
CAUTION
WARNING