Herunterladen Inhalt Inhalt Diese Seite drucken

Control Unit Test - Battery Replacement - SILENTRON Silenya HT 5500 Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 58
Attention! disarming is always full unless the remote controls and keypads are programmed otherwise – If some zones are required to remain
active, they must be armed after disarming has been performed.
Attention! Models with GSM module (5000-5001): disarming could be difficult with additional remote controls/keypads during GSM telephone
transmission following an alarm. In this case disarm using the control unit keypad.
INFORMATION: after every arming and disarming it is possible to have clear vocal information regarding events that have occurred: these are
only possible if the relative messages have been recorded correctly during installation. Failure means:
flat battery/ies: series of successive beeps or vocal message and indication of the control unit display.
doors/windows left open: same as flat battery; it is not mandatory to close the open doors-windows before arming the system.
3,2,3) DISARMING UNDER THREAT (DURESS): Attention! if disarmed by entering a DURESS code the manoeuvre is identical, but the
telephone transmitter is activated, which calls the envisioned users.

3.2.4) CONTROL UNIT TEST - BATTERY REPLACEMENT

There are 3 types of test: CONTROL UNIT (DETECTORS) - DIALLER - FIELD METER. The access to the TEST is also useful for changing the
batteries because in TEST mode the sirens are blocked, therefore there will be no tampering alarm.
A) CONTROL UNIT TEST (empty list): test the remote controls and cause the alarm of all detectors by opening protected doors/windows,
moving in the areas protected by volumetric detectors, interrupting infrared ray barriers and so on, always waiting 10 seconds between one
alarm and the other, up to 99 successive alarms, which remain memorised. If there are several detectors, perform the test in two stages. At the
end check the correct reception of every alarm, checking on the display by means of the arrows ↓ ↑:
13 / 02 / 09
17,00
DISARMED
_ ▄ █
Remote control test:
press the green button
Notes: some models of controls
work in one frequency only
Remote keypad test:
digit arming code and
press the red button
Detector test:
Simulate an alarm condition
The quality of the radio signal is described as follows: H = high ; M = medium; L = low.
In all these cases the system functions correctly: differences in signal are due to distance and physical obstacles between the control unit and
that detector. If there is no indication for one of the frequencies, it is probable that the detector is beyond maximum range or that there are
interferences on that frequency. If there are no indications of either frequency, perform a real test; i.e. the control unit and cause an alarm. Since
the TEST signal is attenuated in accordance with Standard EN50131, the device may be functioning correctly after all: if no alarm occurs, call
for after-sales technical assistance.
Attention! Some detectors transmit the alarm twice: two consecutive signals could occur.
Attention! It is possible that a detector signal is sometimes H (M-L), sometimes M (H-L): this is due to occasional interference or the movement
of persons in the protected rooms during the tests. This occurs often when checking the remote controls, since the position of the remote control
in relation to the control unit is not permanent and therefore, the signal received tends to vary.
Attention! To perform a TEST of the volumetric detectors, no one should be in the protected area for at least three minutes prior to the test,
which is performed by crossing this area: the detector light indicates the alarm, which will be memorised in the control unit.
Attention! Do not forget open protected doors/windows after TEST because during the first successive arming there will be no relative signal.
B) RADIO RECEPTION TEST – INTEGRATED FIELD METER
13 / 02 / 09
17,00
DISARMED
_ ▄ █
During a transmission you can
show the radio signal intensity on
the two frequency
SILENTRON spa – 10139 – Via Sagra S.Michele 25 Torino - ITALIA
ENTER USERCODE
N
1 2 3 4
DISARM
(name)
01
C1 H,
C2
_
↓↑
ARM CODE
(name)
02
C1 H,
C2
M
ALARM
(det. name)
A01
03
C1 H,
C2
H
ENTER USERCODE
N
1 2 3 4
C 1: █ █ █ █ █ █
C 2: █ █ █ █ █ █ █ █
TEST
CONTROL PANEL
DISARM is the transmission of green button
NAME is the label writing during programming - 01 is the 1st transmission
C1 is the signal level on first frequency
C2 is the signal level on second frequency
ARM is the transmission of red button
NAME is the label writing during programming - 02 is the 2nd transmission
C1 is the signal level on first frequency
↓↑
C2 is the signal level on second frequency
ALARM is the type of transmission (TAMPER when opening a box)
A01 is group A detector 1
Other indication as above
↓↑
TEST
CONTROL PANEL
The signal is showed with one to eight signs.
Only one sign is sufficient for a good reception: during TEST the receivers
are in low sensibility condition as request by the EN 50131 (EU rights)
COPYRIGHT SILENTRON DS5500/1/2/3XB090910GM
EMPTY LIST
↓↑
TEST
TEST
↓↑
FIELD METER
↓↑
26

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis