AND
Control unit function useful to greatly reduce the probability of improper alarms: two detectors are installed to protect
the same area and/or passage, programming them in AND on the same channel. The alarm will only occur with the
detection of both devices within the pre-established 30 seconds time. If the detectors are the same type they must be
installed opposite; if different type (different technologies) according to logic.
DETECTOR:
Equipment designed to signal an intrusion, passing, open door/window and any other event which poses a danger.
Equivalent term used in the manual: SENSOR
DETECTOR EXCLUSION Operation which allows to inhibit a detector temporarily (due to failure or other reason) until reset.
EVENTS MEMORY:
Various forms of indelible recording of occurred events, which can have legal value.
FALSE ALARM:
Alarm caused by a defect and/or failure of one or more devices (covered by industrial warranty)
IMPROPER ALARM:
Alarm caused by incorrect positioning, technical limit of device and/or random accidental causes independent of the
equipment itself (not covered by industrial warranty).
HOME AUTOMATION
Electronic/electro-mechanical automation system for activities in the home (lights and household appliances).
PRE-ALARM:
Control panel state prior to actual alarm, caused by detectors programmed with alarm delay or state of the outside
sirens before sounding
TAMPERING
Attempt to open the cases of the appliances of the devices and/or remove them and/or other, with the purpose of
preventing functioning.
TEST
Control unit test condition which blocks all sirens and also allows checks and battery replacements.
2.) SECOND PART - SILENYA HT CONTROL UNITS– GENERAL FEATURES AND FUNCTIONS
This manual describes the features of the control units and consequently the plant: many of these are consequences of the programming
performed during installation. It is the responsibility of the designer and whoever organises the system to agree the functional aspects with the
user, in order to allow effective use, suitable and non-invasive of the peace.
2.1. – PRINCIPAL OPERATING FEATURES
2.1.1) Detectors control: up to 99 wireless detectors can be programmed (up to 198 if programmed in AND), both intrusion, panic/robbery or
technical alarm. The 5000-5002 models also manage various hard-wired detectors through 6 inputs which can be freely coupled to the zones;
their number is a consequence of their consumption: the Silenya control unit disposes of about 300mA to feed hard-wired detectors, therefore
about 10 devices.
2.1.2 – Intrusion alarm zones A-B-C : these zones can be programmable in two different scenarios
A) Programming with outdoor detectors and consequently Outdoor Alarm Function:
Zone A is recommended for outdoor intruder detectors: the sirens warn with acoustic signals without ringing at maximum power.
zone B is recommended for detectors on accesses and zone C for indoor volumetric detectors: both cause GENERAL ALARMS
In this way the user can arm zones A+B when in these places: approach detected by the external sensors is signalled at low volume or with a
vocal message; whenever a protected access is successively forced, the siren is triggered at maximum power.
In the case of improper alarm of the outdoor detectors, the acoustic signals will not be such to disturb, but will remove the "surprise effect" of
intrusion.
B) Traditional programming with all indoor detectors:
In this case all of the detector alarms cause GENERAL ALARM conditions. The intruder detectors can be divided into the three zones A, B, C
depending on the necessity for differentiated arming, considering that the remote controls have the white key that allows to arm zones A+B
automatically and the red key for full arming.
2.1.3) Accessory alarm zones, always active (24/24hrs):
- "Panic" zone to activate outdoor sirens and telephone calls via a remote control or keypad key in case of need.
- "Robbery" zone to exclusively activate telephone calls via a remote control or keypad key in case of need (medical warning also)
- "Technical" zone to control smoke and water detectors or detectors of any other dangerous event, and set a specific and distinguishable alarm.
2.1.4) – Arming/disarming the control unit:
- up to 32 bidirectional remote controls with 4 keys for full arming (A+B+C) and partial arming (A+B) and disarming, with visual confirm LED.
- up to 32 five-digit codes for full/partial arming and disarming, can be used on control unit and keypad, with under-threat function.
- forced arming: it is possible to arm the control unit every day at a pre-set time (FORCED ARMING).
- in the 5000-5002 models it is possible to connect an additional wired electronic or electro-mechanical key.
2.1.5) Control unit acoustic signals and alarms (see also "Telephone part")
The Silenya HT control units speak, therefore the information is supplied in a clear voice: this takes place if the relative messages are recorded
in the installation phase. If the various information is not recorded the information is supplied with brief, long or intermittent acoustic signals (see
individual operations). Using the accessory board code 30029 the information is pre-recorded.