Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Figure 6
1 Limit switch for side brush 1 start
(SB1_a)
2 Limit switch for side brush 1 end
(SB1_e)
Figure 7
1 Running rollers
2 Eccentric
Figure 8
1 Light barrier of drier forward
2 Light barrier of drier in the middle
3 Light barrier of drier behind
If the "drive forward" signal of the position-
ing ramp blinks, then one of the faults men-
tioned below has occurred.
Number of
Fault
blinks
once
Wheel washing 1 not facing outwards
twice
Wheel washing 2 not facing outwards
thrice
Short/ narrow hall switch pressed (Option) The switch has been pressed by a
four times
Press safety switch roof drier
5 times
Frost protection is active
6 times
Vehicle width switch has been pressed
(Option)
38

Faults

DANGER
Risk of electric shock.
Work on electrical plant only to be carried
out by qualified electricians.
Switch the plant to voltage-free before per-
forming any work; in order to do so, switch
the system to "0" at the main switch and se-
cure against restart.
Who may remedy faults?
Operator
Work designated with the sign "Operator"
may only be carried out by persons who
have been instructed in the safe operation
and maintenance on the wash plant
Electricians
Persons with a professional training in the
electro-technical area.
Customer Service
Work designated with the sign "Customer
Service" may only be done by the fitters of
Kärcher Customer Service or fitters who
have been authorised by Kärcher.
DANGER
Risk of electric shock. Switch the system
voltage-free, in addition, switch the main
switch to "0" and secure it against restart-
ing.
Risk of injury due to compressed air escap-
ing unexpectedly. Compressed air contain-
ers and compressed air lines also remain
under pressure after the plant has been
switched off. It is absolutely necessary to
reduce the pressure before starting work
on the plant. To do this, turn off the com-
pressed air supply and use the manual op-
eration to move the wheel wash system in
and out until the pressure has been re-
leased. Then check the pressure gauge on
the maintenance unit for absence of pres-
sure.
Risk of injury from high-pressure water jet
unexpectedly emerging. It is absolutely
necessary to depressurize the high-pres-
sure system prior to working on the system.
Fault display Positioning ramp
Possible cause
Wheel washing is not in basic posi-
tion
person
Check switching bracket and its limit
switch for damages
Frost proteciton is active
Vehicle is too broad or has been po-
sitioned wrongly
13
-
EN
Risk of eye injuries from parts or dirt flying
off. Keep clear off rotating brushes. Gog-
gles must be worn during maintenance
work.
Remedy
Check compressed air supply, check
mechanical components of wheel
washing 1
Check compressed air supply, check
mechanical components of wheel
washing 2
One or more switches have been
pressed; reset switch manually
Check the switch, call Customer Ser-
vice
Washing cannot be done until the anti-
frost temperature is exceeded again
One or more switches have been
pressed; reset switch; re-position the
vehicle

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis