Standard heating/ filtering mode for models without cir-
culation pump
(the display shows the codes F1 to F3)
This mode is normally selected in areas with cold climates where
heating times are longer due to a lower ambient temperature.
In these modes, the water temperature is regulated by the set
temperature, low-speed pump, and heater which turns on as
needed. Once the programmed temperature has been reached,
the heater and the pump go off. they come back on at the next
programmed filtering/heating cycle, or when the temperature
drops below the set value.
Standard heating/ filtering mode for models with circu-
lation pump (available only on J-230, J-270 and J-280)
(the display shows the codes F0 to F3)
The same considerations made for the models without circulation
pump, except that the temperature of the water is controlled by the
set temperature, by the circulation pump and by the heater, which
is activated when necessary. Once the programmed temperature
is reached, the heater shuts off and the circulation pump contin-
ues running, so as to ensure optimal filtering of the water.
Economy heating/filtering mode (all models)
(the display shows the codes F4 to F6)
This mode is normally selected in areas with cold climates where
heating times are longer due to a higher ambient temperature.
In these modes, the water temperature is regulated by the set
temperature, by the pump operating at low speed (or by the re-
circulation pump, if present), and heater only when a programmed
filtering cycle is active.
These modes consume far less energy than standard modes
outlined above.
Lock Modes (L1 - L2)
These modes are designed for use during spa service or to pre-
vent unauthorized use.
Economy skimming/heating modes
I
On the control panel, simultaneously hold down both buttons ( + )
and ( - ) and release.
Press either button ( + ) or ( - ) to select respectively the filter-
ing/heating mode or lock modes L1-L2 described below:
- filtering mode for models without circulation pump
I
Standard heating/filtering mode(F1-F3)
(the heater is automatically activated if necessary)
F1: 4 hours of skimming/heating per day
(one 2-hour cycle every twelve hours)
F2: 6 hours of skimming/heating per day
(one 2-hour cycle every eight hours)
F3: 8 hours of skimming/heating per day
(one 2-hour cycle every six hours)
I
Economy filtering/heating modes
(the heater is activated only during the filtering cycles)
F4: 4 hours of skimming/heating per day
(one 2-hour cycle every twelve hours)
F5: 6 hours of skimming/heating per day
(one 2-hour cycle every eight hours)
F6: 8 hours of skimming/heating per day
(one 2-hour cycle every six hours)
I
Lock modes
L1: Full lock out (de-activates all mini-pool functions)
L2: Partial lock out
(disables the buttons for jets and light to prevent unautho-
rized use of the spa). In this mode, the skimming/heating
mode continues to operate as programmed. The temperature
display flashes when this function is enabled. EXAMPLE: the
"F3" skimming/heater cycle was enabled prior to choos-
ing lock mode. The mini-pool continues to perform the
"F3" cycle until lock mode is cancelled, allowing another
cycle to be selected.
I
To set the time of the first skimming/heating cycle (after pur-
chase of the spa) connect the spa to the power supply two min-
utes before the desired time.
EXAMPLE: If you desire your first filtering/heater cycle to begin at
10:00 AM turn off the spa and turn it back on again at 9:58 AM.
- filtering mode for models with circulation pump (avail-
able only on J-230, J-270 and J-280)
I
Standard heating/filtering mode (F0-F3)
(the heater is automatically activated if necessary)
F0: 5 minutes of filtering per day.
All pumps are activated for this period of time, so as to re-
move any impurities from the pipes).
F1: 1 hour of filtering per day (default)
(a half-hour cycle every 12 hours)
F2: 1 1/2 hours of filtering per day
(a half-hour cycle every 8 hours)
F3: 2 hours of filtering per day
(one half-hour cycle every 6 hours)
I
Economy filtering/heating modes
(the heater is activated only during the filtering cycles)