CAUTION
Do not use the spa if the water temperature is 40 °C or more.
Maintenance of minimum temperature of water in tub and
anti-freeze protection of the pipes ("Smart Winter").
At regular intervals, the system reads the actual temperature. If it
is below the minimum admissible value (14 °C), the heater and the
filtering pump are automatically activated until the temperature
rises above that value.
The pump is turned on, and turns off after 1 minute. During this
cycle the heater is turned off but will be reactivated later.
u The pumps are turned on at preset intervals, depending on
the temperature:
- temperature between 12 and 14 ° C:
Every 2 hours
- temperature between 9 and 12 ° C:
every hour
- temperature between 6 and 9 ° C:
every 30 minutes
- temperatures at or below 6 ° C:
every 15 minutes
NOTES
- If it becomes necessary to turn on the anti-freeze protection dur-
ing the filtering cycles, those cycles will be suspended and they will
resume when the anti-freeze cycle is complete.
- If it is necessary to perform an anti-freeze cycle while a function
activated by the user is in progress, the cycle will be activated 15
minutes after the end of the function.
- If this protection is active, the spotlight may still be turned on.

■ Water filtering

The water needs to be filtered to keep it clean, clear and invit-
ing. The pump runs the water through a cartridge filter in the skim-
mer (see the chapter on "Maintenance of cartridge filter"). This op-
eration takes place based on a cycle during the day (filtering cycle)
which repeats every 24 hours.

General Information

The City Spa ™ also boasts the Clear Ray ™ filter system which
helps disinfect and purify the water; upon starting the pump, the
generator is automatically activated.
The filtration cycle has two phases:
Start
The pump is activated for 1 minute.
Continuation
The Clear Ray ™ filter system is activated for the remainder of
the cycle.

Setting the filtering cycles

To set the filtering cycle:
u Press the
key and hold it down for about 5 seconds. The
display will show the message dx, where "x" indicates the dura-
tion in hours.
u Press keys
or
minimum of 4 to a maximum of 12 hours).
NOTE: press the "Up" key to increase the value or the "Down" key
to decrease it.
u Press the
key once again to confirm the selected value
and to continue the programming of the start delay, compared
to time "0", of the cycle (parameter sy, where "y" indicates the
number of hours).
ATTENTION: the time "0" is the moment at which the spa is pow-
ered on using the main switch, or the moment at which the param-
eters are memorized. for example, you set as the cycle start delay to
"4", it means that filtering will start 4 hours after you turn on the spa,
or after memorization of said parameters.
u Set the start delay time (from a minimum of 0 to a maximum of
23) using keys
or
values entered and then exit programming.
When this function is active, the LED of the respective symbol
will turn on. If the LED is blinking, it means that the cycle has been
suspended, see the relative chapter for more information.
NOTES
The factory settings are the following:
- cycle duration: 4 hours.
- start delay compared to time "0": 6 hours.
If no programming is performed, every 24 hours a 4 hour filtering
cycle is performed in any case, and will start 6 hours after the spa is
turned on.
If there is a power outage, the data in the memory is saved, but
the time "0" will become the moment at which the electricity comes
back on. Therefore, it may be necessary to turn the main switch up
the line from the spa off and back on to re-align the cycle start delay
with the memorized parameters.
It is possible to vary the filtering cycle setting parameters
at any time by following the procedure provided at the begin-
ning of this chapter. By modifying these parameters, time "0" is
"shifted" to the time in which the new values are saved.
For example: if you set the value of "s" (start delay) to 8, the new
cycle will start 8 hours after the instant at which the new value is
saved. IT IS also possible to reduce to 0 the value of parameter "s": in
this case, the filtering cycle will start immediately.

Suspending the filtering cycles

u The filtering cycle is suspended by activating the pump and/or
by turning on the spotlight. It will restart 10 minutes after the func-
tion is turned off, from the point at which it was stopped. This means
that if 1 hour remained in the cycle when it was interrupted, when it
restarts, it will continue for this time and then stop.