48 | WBE 4200 | Auto-diagnosis menu
In order to check the correct functioning of the
potentiometer, pull out the gauge and check that
during the stroke the value does not get blocked.
!
You need to check the values of the potentiometers
when you insert the measures and the machine
shows unacceptable values and when the problem
persists even after the calibration.
Diagnosis distance potentiometer (4)
Defect
The value remains blocked
at scale end or between 0
and 40.
The value remains blocked
between 40 and 4095.
The value starts from
ex.1500 and blocks at the
end of the scale.
!
After having replaced the potentiometer or after
having detected that the fastening screw is loose,
before proceeding with calibration, follow the
instructions reported here.
7.4.5

5 - Signal of the potentiometer of the width

Diagnosis width potentiometer (5)
Defect
The value remains blocked
at scale end or between 0
and 40.
The value remains blocked
between 40 and 4095.
|
1 695 600 091
2012-11-16
Correction
R
Check that the cable is
correctly connected.
R
Check that the steel cable is
in its seat and is not cut.
R
Replace the connection
cable.
R
Replace the potentiometer.
R
Check that the ring nut is
correctly fixed.
R
Replace the connection
cable.
R
Replace the potentiometers
unit.
Reposition the potentiometer.
(See the following
Instructions).
Correction
R
Check that the cable is
correctly connected.
R
Check that the ring nut is
correctly fixed.
R
Replace the connection
cable.
R
Replace the potentiometer.
R
Check that the ring nut is
correctly fixed.
R
Replace the connection cable.
R
Replace the potentiometer.
7.4.6

6 - Signal of the potentiometer of the diameter

Diagnosis diameter potentiometer (6)
Defect
The value remains blocked
at scale end or between 0
and 40.
The value remains blocked
between 40 and 4095.
The values passes from 0
during the run.
!
NOTE: if, by chance, the nut looses and the
potentiometer disconnects from the shaft, the
machine will no longer read any measure because
the carriage of the potentiometer remains at the
end of the stroke. So, follow the instructions for
"positioning diameter potentiometer".
7.5

CNT

The abbreviation indicates the counter of launches
made by the balancing machine.
In order to move inside the function, use <RIM
DISTANCE>.
Left Display
Right Display
CNT
1
500
6
!
By pressing the <DIAMETER> key and the + key,
the L00P function activates, making it possible to
perform a resistance test: the machine will perform
a launch every 60 sec and, should a difference above
5 g be detected compared to first measurement
cycle, it will lock in automatic highlighting the
wording Err0.
7.6

LED

The abbreviation indicates the "led" lights test of the
board. In order to move inside the function, use <RIM
DISTANCE>.
Correction
R
Check that the
potentiometer is correctly
fixed to the measurement
arm.
R
Replace the connection
cable.
R
Replace the potentiometer.
R
Check that the
potentiometer is correctly
fixed to the measurement
arm.
R
Replace the connection
cable.
R
Replace the potentiometer.
Re-position the potentiometer
(see following Instructions).
Description
Press <RIM DISTANCE> to roll
down the menu
Number of overall launches
ex:1500)
Number of daily launches, since
the machine has been started)