Calibration with sample weight

i
After Calibration of electronic vernier caliper remove
the wheel from machine.
1. Press the button
until the LED of
flash;
2. Bring the calliper gauge on the flange.
B
Fig. 31:
3. Bring the calliper gauge back to the"Rest position";
Fig. 32:
4. Close the wheel protection cap.
 Measurement is started.
 The left-hand display shows C-3.
5. Apply the sample weight on the internal side of the
flange.
6. Close the wheel protection cap..
 Measurement is started.
 The left-hand display shows C-4.
7. Remove the sample weight from the internal side
of the flange and apply it on the external side (12
o'clock).
8. Close the wheel protection cap.
 Measurement is started.
 The left-hand display shows C-5.
9. Turn the flange until the weight is in 12 o'clock
position and then press <SPLIT>.
 The left-hand display shows 0-0.
Robert Bosch GmbH
"
Calibration is completed.
i
The performed calibration is automatically and
permanently saved.
i
After having carried out factory calibration with
button
sample weight, access the standard calibration menu
and perform a new calibration.
Maintenance | WBE 4200 | 59
1 695 600 091
en
|
2012-11-16