Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

7 P R E S S U R E R E G U L AT I N G ( S B H - G )
The pressure is variable setable from approximately 60 bar with a turnover from
2 l/min. to the maximum capacity as it been indicated on the machine.
8 WO R K I N G S H O U R S C O U N T E R
The workings hours counter is situated at the front at the control panel. The
counter shows the number of hours that he machine has worked.
9 R E S E T B U T TO N ( S B H - G )
The reset button is an illuminated push button. If the reset button is being
pushed during 3 seconds (or more) , you receive an error message where the
fault can be determined by means of a flash frequence.
10 G A S VA LV E I N D I C AT I O N L E D ( S B H - G )
The indication led lights up when the gas valve is opened and the burner is
active.
11 S P R AY I N G TO O L S
The hp- spray gun have been carried out with a grey handle
• not spraying: release the lever in the handle.
• Spraying: pressing the lever in the handle.
• Spray security: slap the block-system out in the lever.
Checks during praying regularly or the lance coupling still sits firmly on the gun.
The machine is standard provides with a single lance.

SET TO WORK

SBH-D

1
• put the high pressure cleaner as much as possible in a horizontal position.
• Connect the spray gun with the high pressure hose (without spray lance) to
the high pressure cleaner.
• Connect the high pressure cleaner electrical (plug in socket, 230/400V).
• Turn the main switch to position 1=on.
• aim the spray gun in to the free space and operate the spray gun until the
water jet is completely de aerated (+- 30 sec.).
• Turn the main switch to position 0=oFF.
• Connect the spray lance to the spray gun.
• Turn the main switch to position 1=on.
• operate the spray gun and check the working pressure on the pressure
gauge. adjust if necessary the pressure regulator for the right spray pressure.
• For the use of hot water one must turn the main switch to position 2=BuRnER.
• adjust at use of hot water the temperature regulating button tot the desired
position.
• adjust the concentration from the added chemicals by opening the mixing
valve on the spray lance to your needs.
DiBO 19
E N
aC T I VaT I o n    

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis