Herunterladen Inhalt Inhalt Diese Seite drucken

Error And Warning Messages - Yamaha RX-V3900 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 281
Optimizing the speaker setting for your listening room
Parameter
Distance
This unit checks and adjusts the distance of
each speaker from the listening position and
(Speaker distance)
adjusts the timing of each channel.
Size
This unit checks and adjusts the frequency
response of each speaker and sets the
(Speaker size)
appropriate low-frequency crossover for
each channel.
Equalizing
Parametric equalizer adjusts the level of the
specified frequency bands. This unit
(Speaker
automatically selects the crucial frequency
equalizing)
bands for the listening room and adjusts the
level of the selected frequency bands to
create a cohesive sound field in the room.
Level
This unit checks and adjusts the volume
level of each speaker.
(Speaker level)
5
If you have finished the settings, press 9l
to return to the previous menu level and then
press 9n to select "Start".
Before proceeding next operation
Once you perform the next operation, this unit starts the
automatic setup procedure in 10 seconds. During the
automatic setup procedure, do not perform any operation on
this unit. For more accurate measurements, we recommended
that you get out of the room or move to the wall where
speakers are not around during the measurement. It takes
approximately 3 minutes.
6
Press 9ENTER to start the measurement.
This unit starts to count down from 10 seconds.
y
• To start the measurement immediately, press 9ENTER
again.
• To cancel the automatic setup and return to the previous
screen, press 0RETURN.
Loud test tones are output from each speaker during
the measurement. Once all items are measured,
"Measurement Completed Successful" appears.
Equalizing
Level
Result
Note
If an error or warning message appears, see "Error and
warning messages" (page 32).
32
En
Descriptions
Measurement Completed
Sucessful
Detail:
[ ]
Exit:ENTER
Pre Check
Main Check
Wiring
7
Press 9ENTER to exit from the "Result"
screen.
y
• To view the measurement results in detail, press 9h.
Press 9k / n repeatedly to toggle between parameters
(page 35). Press 9l to return to the "Result" screen.
• To retry the measurement from step 4, press 9k.
8
Press 9l to save the measurement results
or 9h to discard them.
9
Press IMENU to turn off the GUI menu and
disconnect the optimizer microphone.

■ Error and warning messages

If an error or warning message appears during the
automatic setup procedure, carry out one of the following
operations. For details on each message, see "Automatic
setup" (page 113).
• To view the details on the error and warning messages,
press 9h. Press 9k / n to display the previous/next
page (if available). Press 9l to return to the previous
menu level.
• To return to the GUI menu, press 9l.
• To retry the measurement, press 9k.
• To ignore the message and continue the process, press
9n.
Note
Some operations cannot be performed depending on the type of
error (or warning).
Retry
Exit
Detail
E09:User Cancel

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis