Taste:
Printhead up time
Key:
Printhead valve reaction
time
Taste:
Print offset border
calculation
Taste:
Ribbon motor stop delay
time
Key:
Field ribbon saving
Rewind speed
Key:
Ribbon save priority
Key:
Speed 1 field
Key:
Tension
Key:
Save start signal in
normal mode
PHupT = printhead up time in ms:
Is used from ribbon save algorithm to calculate if a field ribbon save can be made or not.
PhVReactT = valve reaction time in ms:
The time is calculated when to start with printhead upward movement.
Calcoff = Turn On/Off print offset border calculation:
If this parameter is set to Off, then a smaller offset as the required print offset can be entered.
RibMotStpDlayT = ribbon motor stop delay time
Delay time in ms in which the transfer ribbon motor is still moved with constant speed before
stopping.
FieldRS = field ribbon saving:
Off: Field ribbon save switched off.
Normal: Field ribbon save is only accomplished if the transfer ribbon motor can be completely
stopped.
PHOnly: Only the printhead is moved. The transfer ribbon does not stop.
Strong: Field ribbon save is even accomplished if the transfer ribbon motor cannot be stopped.
Rwind v = rewind speed in mm/s:
Indication of rewind in mm/s.
Ribbon Save Quality:
If the ribbon save algorithm is not able due to fast changes in material speed to keep the
demanded ribbon save (ribbon correction) then the printout can be shifted to obtain the
demanded transfer ribbon saving.
Print Position:
If the ribbon save algorithm is not able due to fast changes in material speed to keep the
demanded ribbon save (ribbon correction) then the print position can be kept by an increased
transfer ribbon use.
If 0 (default value) is set, the parameter has no influence to the ribbon save.
Indication of length that is transported forwards after measuring the transfer ribbon.
SaveStartInNormMode:
If a start signal comes during the printing process the print is not interrupted but the print for the
start signal is attached directly to the current print.