Herunterladen Inhalt Inhalt Diese Seite drucken

Switching Off - Stertil koni ST 1075-FWF Bedienungsanleitung

Mobile hebesäule
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 74
2.
Press the second button at the bottom of the settings screen.
The second user settings screen appears.
3.
Position the column at the required height.
4.
Lower the column lift into the pawls and then raise it approx. 25 mm, to make sure
that the highest position is well above the locking position.
5.
Enable the programmable height limit function (set it [ON]) and exit the service
menu.
The setting is switched [ON] for all the columns in the set. The current height is set
as the height limit for each column, even if the current height has been set higher or
lower with the [SINGLE] or [PAIR] functions. This therefore means that the other
columns can have a height limit that is different from the height limit for the column
that they were adjusted to.
5.6

Switching off

Turn the main switch off when the columns are not in use.
The (slight) power consumption of the controller can discharge the batteries, so that
raising and lowering become impossible.
The system switches itself off if complete discharge is imminent.
When using just one or two column lifts (when operating in pairs), make certain that
there is no possible risk of instability; see also section Safety when hoisting (on
page 27). If in doubt, ask your supervisor.