1-5-2. Removing and Mounting the Side Panel

Preparation:
Phillips-head screwdriver (No.2), service key (attached goods)
1. Loosen the ten fixing screws on the side panel.
Loosen four screws on the side panel until they
are free to spin. The screws do not detach from
the panel.
2. Unlock the side panel.
Unlock the cover using the service key.
3. Remove the side panel.
The side panel is fixed in place by hooks at the
bottom (in 2 locations). Tilt the side panel toward
you and pull up to remove it. Do not use force
when tilting the side panel.
This completes removing the side panel. To mount the side panel, perform the removal procedure in reverse. Make
sure that you do not forget to tighten the screws or to lock the key lock.

1-5-3. Removing and Mounting the Filter Cover

Refer to "6-3-1. Cleaning the Air Filter" (→ page 94) for details on how to remove and attach the filter cover.