                                  AF811 Gel Full Face Mask
                                  Intended Use
                                  The AF811 Gel Full Face Mask is intended to provide an interface for application of CPAP
                                  or bi-level therapy to patients. The mask is for single use in the hospital/institutional
                                  environment only. The mask is to be used on patients (>66lbs/30kg) for whom CPAP or bi-
                                  level therapy has been prescribed.
                                  Note: An exhalation port is not built into the AF811 Gel Full Face Mask. A separate
                                  exhalation device must be used with this mask.
                                  Note: This mask does not contain natural rubber latex or DEHP.
                                  Caution: U. S. federal law restricts this device to sale by or on the order of a physician.
                                  Symbols
                                  Warning or
                                  Caution
                                  Does not contain
                                  natural rubber latex
                                  Warnings:
                                  • This mask is not suitable for providing life support ventilation.
                                  • This mask requires a separate exhalation device.
                                  • This mask is designed for use with CPAP or bi-level systems recommended by your health
                                  care professional or respiratory therapist. Do not wear this mask unless the CPAP or bi-level
                                  system is turned on and operating properly. Do not block or try to seal the exhalation port.
                                  Explanation of the Warning: CPAP systems are intended to be used with special masks with
                                  connectors which have vent holes to allow continuous flow of air out of the mask. When the
                                  CPAP machine is turned on and functioning properly, new air from the CPAP machine flushes
                                  the exhaled air out through the attached mask exhalation port. However, when the CPAP
                                  machine is not operating, enough fresh air will not be provided through the mask, and exhaled
                                  air may be rebreathed. This warning applies to most models of CPAP systems. Rebreathing of
                                  exhaled air for longer than several minutes can, in some circumstances, lead to suffocation.
                                  • If oxygen is used with the device, the oxygen flow must be turned off when the device is not
                                  operating. Explanation of the Warning: When the device is not in operation, and the oxygen
                                  flow is left on, oxygen delivered into the ventilator tubing may accumulate within the device
                                  enclosure. Oxygen accumulated in the device enclosure will create a risk of fire.
                                  • Oxygen supports combustion. Oxygen should not be used while smoking or in the presence
                                  of an open flame.
                                  • At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen concentration will vary,
                                  depending on the pressure settings, patient breathing pattern, mask selection, and the leak
                                  rate. This warning applies to most types of CPAP and bi-level machines.
                                  • Some users may experience skin redness, irritation, or discomfort. If this happens, discontinue
                                  use and contact your healthcare professional.
                                  • The patient's physician should be contacted if the patient experiences the following
                                  symptoms while using the masks or after removing it: Unusual chest discomfort, shortness
                                  of breath, stomach distension, belching, or severe headache; drying of the eyes, eye pain, or
                                  eye infections; blurred vision. (Consult an ophthalmologist if
                                  symptoms persist.)
                                  • At low CPAP or EPAP pressures the flow through the exhalation
                                  Consult instructions
                                  Note
                                  for use
                                  Do Not
                                  Reuse
                                  Leak symbol
                                  and value
                                  E N G L I S H
                                  1

                                  Werbung

                                  Inhaltsverzeichnis
                                  loading

                                  Inhaltszusammenfassung für Philips Respironics AF811

                                  • Seite 10 Verwendungszweck • Diese Maske sollte nicht an Patienten verwendet werden, die nicht kooperieren, betäubt sind, nicht Die AF811 Gel-Vollgesichtsmaske ermöglicht die Beatmung des Patienten bei CPAP- oder reagieren oder nicht in der Lage sind, die Maske abzunehmen. Bi-Level-Therapie. Die Maske ist nur zum einmaligen Gebrauch in Krankenhäusern und •...
                                  • Seite 11 Respironics AF811 Maske mit Capstrap-Halterung, Grösse S, 1 STK. Hinweise: 1063051 Respironics AF811 Maske mit Capstrap-Halterung, Grösse L, 5 Stk./ Pkg. • Die Bänder fester ziehen, wenn bei Stellungsänderungen Luftlecks auftreten. 1063052 Respironics AF811 Maske mit Capstrap-Halterung, Grösse M, 5 Stk./ Pkg.
                                  • Seite 12: Beabsichtigtes Leck

                                    Vorgaben oder mit inkompatiblen Geräten kann den Tragekomfort der Maske und die Effektivität der Dichtung mindern, eine optimale Therapie verhindern und die Gerätefunktion durch Lecks bzw. Schwankungen der Leckrate beeinträchtigen. Beabsichtigtes Leck Druck-/Fluss-Diagramm AF811 mit Whisper Swivel II AF811 Einweg-Ausatemventil (DEP) Druck in cm H O (hPa) Druckabfall in cm H...
                                  • Seite 84 Respironics Inc. Respironics Deutschland 1001 Murry Ridge Lane Gewerbestrasse 17 1071654 R06 Murrysville, PA 15668 USA 82211 Herrsching, Germany LZ 4/30/2014...

                                  Inhaltsverzeichnis