Herunterladen Inhalt Inhalt Diese Seite drucken

Installation; Bme Hp Feed Pump; X-Changer Module - Grundfos BMEX Series Montage- Und Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25

5. Installation

The BME hp feed pump and X-Changer modules can be mounted
directly on the floor or a base frame. The units are adjusted by
means of the four adjustable feet.
The inlet and discharge ports of the units are shown in figs
6. Pipes are connected by means of Victaulic/PJE clamp
couplings.

5.1 BME hp feed pump

Adjustable feet ± 10 mm
Fig. 2
BME hp feed pump
If the pump is to be fastened, the following procedure is
recommended:
Fasten the pump with four foundation bolts. The base
frame has additional holes for this purpose. The bolts
Note
can be secured to a concrete foundation or welded
onto a steel floor. See figures
Prior to startup, the nuts should be slackened. See
Note
fig.
3
concrete foundation and fig.
nuts must be counter-locked.
Base frame
Fig. 3
Concrete foundation
6
2
and
The nuts must be tightened during transportation. See fig. 5.
Inlet
Discharge
Base frame

5.2 X-Changer module

3
and 4.
4
steel floor. The
Base frame
Fig. 4
Steel floor
Base frame
Fig. 5
Tightened nuts
Low-pressure
inlet
High-pressure
discharge
High-pressure
inlet
Low-pressure
discharge
Adjustable feet
Fig. 6
Example of X-Changer module (2 x 180/220)
Nuts
Base frame

Werbung

Inhaltsverzeichnis
loading