Herunterladen Inhalt Inhalt Diese Seite drucken

PeakTech 1145 Bedienungsanleitung Seite 63

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Pk-Pk :
This displays a Peak to Peak value of the waveforms of the currently displayed channels. That is, absolute gap
between maximum and minimum amplitude is displayed with volt. When input signal is out of the ADC input range , "?"
is displayed. Maximum value and minimum value are equal, "Invalid" is displayed.
RMS :
This displays a Root Mean Square value of 1 cycle of the waveforms of currently displayed channels. When range of
input signal is out of the ADC input range, peak to peak value is less than 2 division, or width of 1 cycle is less than 0.4
division on display, "?" is displayed. When 1 cycle is not captured, "Invalid" is displayed.
Mean :
This displays a mean value of 1cycle of currently displayed waveforms. When range of input signal is out of the ADC
input range, peak to peak value is less than 2 division, or width of cycle is less than 0.4 division on display, "?" is
displayed. When 1 cycle is not captured, "Invalid" is displayed.
Frequency :
This displays a frequency value of 1 cycle of currently displayed waveforms. When range of input signal is out of the
ADC input range, peak to peak value is less than 2 division, or width of 1 cycle is less than 0.4 division on display, "?"
is displayed. When 1 cycle is not captured, "Invalid" is displayed.
NONE :
This cancels the measuring functions of parameter.
Rising Time :
This displays a rising time of currently displayed waveforms. When range of input signal is out of the ADC input range,
peak to peak value is less than 2 division, or width of 1 cycle is less than 0.4 division on display, "?" is displayed. when
1 cycle is not captured, "invalid" is displayed.
Falling Time :
This displays a falling time of currently displayed waveforms. When range of input signal is out of the ADC input range,
peak to peak value is less than 2 division, or width of 1 cycle is less than 0.4 division on display, "?" is displayed.
When 1 cycle is not captured, "Invalid" is displayed.
Period :
This displays a period of 1cycle of currently displayed waveforms. When range of input signal is out of the ADC input
range, peak to peak value is less than 2 division, or width of 1 cycle is less than 0.4 division on display. When 1 cycle
is not captured, "Invalid" is displayed.
+ Width :
This displays a positive width of 1 cycle of currently displayed waveforms. When range of input signal is out of the
ADC input range, peak to peak value is less than 2 division, or width of 1 cycle is less than 0.4 division on display, "?"
is displayed. When 1 cycle is not captured, "Invalid" is displayed.
- Width :
This displays a negative width of 1 cycle of currently displayed waveforms of channel. When range of input signal is
out of the ADC input range, peak to peak value is less than 2 division, or width of 1 cycle is not captured, "Invalid" is
displayed.
Duty :
This displays a duty ratio of 1 cycle of currently displayed waveforms of channel. When range of input signal is out of
the ADC input range, peak to peak value is less than 2 division, or width of 1 cycle is less than 0.4 division on display,
"?" is displayed. When 1 cycle is not captured, "Invalid" is displayed.
5.7. SAVE/RECALL
This function is able to save waveforms and setup conditions of present
working environment and they can be recalled by the user. It is used in
setting simple working environment and for waveform comparison. The
saved information could be preserved for a time even if the inside
battery is completely discharged or disconnected from the main body.
-21-

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

11651155115011701160

Inhaltsverzeichnis