REGULAR MAINTENANCE SCHEDULE
1.- Clean: the silicone gasket, door disk and the chamber/silicone
gasket contact area.
WEEKLY
2.- General cleaning of the external surfaces.
3.- Cleaning of the sterilisation chamber.
4.- Cleaning of the trays and support.
500 CYCLES
5.- Replacement of the bacteriological filter.
1,000 CYCLES
6.- Replace the silicone gasket on the door.
1.- Clean: the silicone gasket, door disk and the chamber/silicone gasket contact area.
Clean parts with a damp cloth (do not use alcohol). Do not let dirt get accumulated because
it can affect the leak tightness on the door and consequently the silicone
gasket can bend or break.
2.- General cleaning of the external surfaces.
Clean all the external parts using a damp cloth with common neutral detergent (do not use
abrasive or corrosive products). Do not clean the autoclave directly with
pressurised water to avoid it leaking into the machine.
3.- Cleaning of the sterilisation chamber.
4.- Cleaning of the trays and support.
Carefully clean the sterilisation chamber, the tray support and the trays (or sterilisation
vessels) with a damp cloth or with common neutral soap. Then rinse them with alcohol and
finally with water.
IMPORTANT: Do not use disinfectant products to clean the chamber.
5.- Replacement of the bacteriological filter.
In places where there is a lot of dust, replace the bacteriological filter more frequently.
REMOVING THE FILTER
PLACING THE FILTER
Turn the bacteriological filter anticlockwise to remove it.
Screw the new filter in clockwise.
Reset the machine as described in section 4.3.6.5.
6.- Replacement of the silicone gasket on the door.
IMPORTANT: the silicone gasket or the metal surfaces around it could be hot; make sure
before starting that the autoclave is at room temperature.

7. TROUBLESHOOTING

Some possible faults that are not included in the warnings described in section 5 are the following:
PROBLEM
The main switch is off.
The autoclave does
There is no electric current where the autoclave is connected.
not work.
The lead is not connected properly to the power supply.
There is no electric current where the autoclave is connected.
The main switch
does not come on,
The lead is not connected properly to the power supply.
it returns to the
position '0'.
An internal security thermostat has been activated.
To replace the silicone gasket on the door:
1. Remove the gasket by pulling the flange.
2. Clean the groove with a damp cloth.
3. Place the new gasket manually in two places, top and bottom at 180º, and spread the
gasket evenly in the groove.
4. Repeat step 3 from another two places at 90º from the previous ones.
5. Place the rest of the gasket in the groove.
6. When it is in place, go to the main menu and close the door so it fits in perfectly.
Reset the machine as described in section 4.3.6.5.

6.2. PREVENTIVE MAINTENANCE

The QUAZ autoclave requires Preventive Maintenance by the Authorised Technical Support
every 1,000 cycles.
The autoclave gives a warning 50 cycles before maintenance is required. This message will
be repeated every 10 cycles, only once a day, until the maintenance is carried out.
For this kind of maintenance, the SATELEC - ACTEON Group Authorised Technical Support
will carry out a general inspection of the machine, clean inside the distilled water and
waste water tank, clean the internal filters, etc. as required.
CAUSE
SOLUTIONS
Put the main switch on.
Restore the supply.
Connect the lead properly.
Contact the electricity supplier.
Connect the lead properly.
Allow the machine to cool down and try to connect it again.