7.9
Assembly of hydraulic line
New hydraulic line
with packed connecting nipples [52].
WARNING
Guide hydraulic line
[53]
in back wall of housing.
Pull hydraulic line
above the solenoid valve.
Turn and guide hydraulic line
position relative to pipe interruptor.
Remove protective packaging from both connecting
nipples.
WARNING
Slide connecting nipple
interruptor [30].
(also refer to section
Clip the pipe interruptor
into the holder [32].
7.10
Peristaltic pump
7.10.1
Replacing the peristaltic hose
Unscrew and remove the suction/pressure line
Swivel lever
Pull pump housing
Fig. 7.49
417102228_Ecoplus-S
[51]
(module spare part) is supplied
Never bend the connecting hose [51].
Do not turn connecting nipple in tube.
Do not remove protective packaging from
connecting nipple until hydraulic line is
correctly positioned in the unit.
[51]
from below up through aperture
[51]
upwards and sideways out of shaft
[51]
into correct installation
Fragile hydraulic lines.
Never bend of apply force.
Connecting nipples must not be turned inside
the tube. Do not degrease, soil or damage the
O-rings.
[52]
fully into the dismantled pipe
7.5.1
'Removal'.
[30]
and connecting nipples
[53]
upwards (Fig. 7.48).
[54]
upwards to remove (Fig. 7.48).
Remove peristaltic hose [55].
Do not twist hose while doing so.
Clean pump housing, base plate
and rotor [56].
Grease new peristaltic hose
rotor
[56]
with silicone grease.
Install lubricated peristaltic hose
pump housing.
Unscrew and remove the
suction/pressure line
- 46 -
Fig. 7.43
Fig. 7.45
Fig. 7.46
Fig. 7.47
[52]
Fig. 7.48
[55]
and
[55]
in
Fig. 7.44
Rev 01-08.12