AP10
Installation
PIN
1
2
3
4
Fig. 6: Pin assignment
Data transfer RS485 interface
RS485 baud rate
115.2 kbit/s
57.6 kbit/s
19.2 kbit/s
Data transfer CAN interface
CAN baud rate
125 kbit/s
250 bit/s
500 bit/s
1 Mbit/s
Strand cross sections of lines ≥0.14 mm²- ≤0.5 mm².
Earthing connection (PE)
For protection against interference, the screens of the signal lines and the
power line must be connected on both sides. Potential differences cause
inadmissible currents on the screen. Install the PE connection
protective earth conductor potential between the plug connectors (see
Fig.
(not in the scope of delivery). For multiple position indicators we recom-
mend connecting the earthing to a ground bar
AP10 · Date 25.09.2014 · Art. No. 86832 · Mod. status 356/14
Designation
DÜB/TxRx-/CANL
DÜA/TxRx+/CANH
+UB
GND
max. bus network length
200 m
400 m
1200 m
max. bus network length
320 m
160 m
80 m
40 m
6). Use 6.3 mm flat connectors with short strands 2.5 mm² ... 4 mm²
viewing side = plug-in side
1
(see
English
Bus IN
Bus OUT
Bus IN
1
Bus OUT
2
3
PE connection
onto the
3
Fig.
7).