Accessory connector

NOTICE
8 Accessory connector
(not included in the scope of delivery)

8.1 Straight matting connector M8

Advice
` Strand cross sections of lines ≥0.14 mm² - ≤0.25 mm² / cable feed-
through: ø3.5 - ø5 mm.
• Accessory SIKO art. no. "84209" (female 4 pin bus IN).
• Accessory SIKO art. no. "84210" (pin 4 pin bus OUT).
Mounting
(Fig.
10)
1. Slide parts
1
...
2. Strip the cable.
3. Shorten, expand the shielding and lay around the shielding ring
4. Run strands through coupling sleeve
5. Mount parts
2
...
6. Thread insulating sleeve
sleeve.
7. Screw coupling sleeve
.
1
Fig. 10: Straight matting connector M8

8.2 Mating connector M8 bus terminator

For the fieldbus to function, a terminating resistor is required (120 Ohm).
• Accessory SIKO art. no. "BAS-0005" (pin 4 pin).
For multiple position indicators on one bus: connect terminating plug to
bus OUT of the last bus station (see chapter 4.2).
For one position indicator: connect terminating plug to bus OUT (see chap-
ter 4.2).
AP10 · Date 25.09.2014 · Art. No. 86832 · Mod. status 356/14
4
over cable sheath.
5
4
. Turn pressure screw
, solder strands and mount insulating
6
5
with element
and strip them.
1
to secure the cable.
7
and tighten pressure screw