Herunterladen Inhalt Inhalt Diese Seite drucken

Battery Change; Battery, Function And Service Life; Operating States - Siko AP10 Originalmontageanleitung

Absolute / elektronische positionsanzeige
Vorschau ausblenden Andere Handbücher für AP10:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

AP10

Battery change

6 Battery change
Inflammable, danger of explosion and burns
DANGER
` Do not recharge the battery nor expose it to temperatures above
` Dispose of used batteries properly.
Danger of short circuit
CAUTION
` Do not insert sharp or metallic objects into the inside of the housing
Loss of data
CAUTION
With missing supply voltage and empty or missing battery, calibration of
the sensor unit will be lost.
` It is mandatory to change the battery with supply voltage switched on.
` Repeated calibration travel in case of data loss (refer to the see User

6.1 Battery, function and service life

• SIKO battery unit order number: art. no. "84208".
The battery enables capturing of the absolute position value as well as the
detection of currentless shaft adjustments. The average battery service
life is approximately 5 years depending on the ambient conditions and
duration of position indicator supply voltage application. The battery can
be changed at SIKO distribution partners, in the SIKO parent factory or by
yourself.

6.2 Operating states

Battery symbol
In standard operation, ~3 months are left until the battery will be comple-
tely discharged.
Battery symbol
AP10 · Date 25.09.2014 · Art. No. 86832 · Mod. status 356/14
85 °C.
in case of remote battery compartment.
manual for the procedure).
blinking:
glowing:
Battery nearly empty
Replace battery
English