AP10
24
Installation
CAUTION
Loss of type of protection/shielding
Insufficient tightening torque of the mating connector can result in loss of
type of protection and / or shielding.
` Tighten the mating connector with at least the following tightening
torque:
M8 connector
or refer to the manufacturer's instructions for the connector.
Preparing mounting
1. Make the bore ød for torque support
shaft
2
.
2. Pay attention to the diameter øD of the drive shaft
Mounting
(Fig.
1,
Fig.
1. Push the position indicator incl. sealing plate onto the shaft
reaching the stop. Insert torque support
(non-distorted mounting). A long hole for the torque support is recom-
mended.
2. Tighten grub screws M3
Fig. 1: Mounting dimensions
Fig. 2: Mounting
AP10 · Date 25.09.2014 · Art. No. 86832 · Mod. status 356/14
≥0.2 Nm
(Fig.
1,
Fig.
2,
Fig.
3):
1
2,
Fig.
3):
3
with max. 0.2 Nm.
Fig. 3: Fastening torque
for screws
at distance L1 to the drive
.
3
2
1
into the existing bore
dim. ød ø6
(type A)
H8
ø10
(type B)
+0.8
dim. L1 22 or 30
(±0.1 at type A)
dim. øD ø20
(clearance fit)
Tab. 1: Mounting dimensions
1
Torque support
Shaft
2
3
Grub screw
English
until