30
Commissioning
Configuration parameters CAN
Parameter Value range
Id
1 ... 127
bAUd
125, 250, 500,
800, 1000kbd,
Auto
CodE
0 ... 999999
000100
011100
Configuration parameters RS485
Parameter Value range
Id
1 ... 31
bAUd
19.2, 57.6,
115.2
PrtCL
Sn5, SEruiC
BUSto
0 ... 20
InHbt
0 ... 10
CodE
0 ... 999999
011100

5.1 Calibration

Two steps are required for executing calibration:
1. Write calibration value via bus interface (see User manual)
=> Position value = current measured value + calibration value + off-
set value
2. Execute calibration (reset) (see chapter 5: Display and control keys
and Additional)
=> Position value = 0 + calibration value + offset value
Since the measuring system is an absolute system, calibration is necessary
only once with commissioning.
AP10 · Date 25.09.2014 · Art. No. 86832 · Mod. status 356/14
Default Meaning/Remark
127
bus address
NOTICE
Restart is required after chang-
ing these parameters!
Auto
CAN baud rate (e. g. 250 kbit/s)
0
for test/diagnosis purposes
start calibration travel (see
chapter 5.1)
load factory settings
Default Meaning/Remark
31
bus address
NOTICE
Restart is required after chang-
ing these parameters!
57.6
SIKONETZ baud rate (e. g.
57.6 kbit/s)
Sn5
SIKONETZ protocol
0
Bus Timeout
0
Response delay
0
for test/diagnosis purposes
load factory settings