g) Measured data (data logger)

The recorded electrical measured data can be retrieved with the 'Recording' function in the settings menu.
The measurement series can be selected and displayed as a trend-plot with the 'Retrieve' menu item under 'Record-
ing' in the settings menu.
The measurement series can be selected with the cursor buttons </>.
A graphical display as a trend-plot ('TREND') can be displayed with the 'MODE' button.
Use the middle cursor button ^ ('DELETE') to delete the measurement series. The 'HOLD' button closes the display
('CLOSE').
The trend display displays the measured values as an XY graph. Each recording step can be selected with the cursor
buttons </>. The corresponding value is displayed at the bottom left.
A zoom factor of 1-4 can be set with the middle cursor button 'ZOOM'. This elongates the time axis.
The HOLD button ('CLOSE') closes the display.

h) Deleting measured data (data logger)

The recorded electrical measured data can be deleted with the 'Recording' function in the settings menu.
The measurement series can be deleted in full with the 'Delete all recordings' menu item under 'Recording' in the
settings menu. Individual measurement series can be deleted via the Retrieve menu.
Select the 'Delete all recordings' item and confirm with the menu button.
To delete all measurement series, press the '<' cursor button until 'Yes' is highlighted orange. Confirm with the menu
button. Selecting 'No' cancels the deletion.
The current memory parameters can be read out via the 'Memory' menu item. This is necessary as the internal
memory space in the measuring instrument is limited.
i) LED light
An LED light is integrated into the DMM for illumination of dark areas or objects at the rear of the device.
The light can be switched on and off by pressing the 'IR' button (11) for approx. 2 s. The LED light remains switched on
until deactivated manually, until the measuring instrument is switched off or until the active automatic shut-off function
on the measuring instrument switches it off.
j) Automatic shut-off feature
The DMM allows automatic shut-off after a preset time. This function saves battery power and extends the service life.
The automatic shut-off function can be disabled to allow longer measurements to be carried out.
Press any button to switch the DMM back on after it switches off automatically.
Automatic shut-off can be set with the 'Auto Power OFF' menu item in the settings menu.