17 Technical data

Display ........................................................... 4000 Counts (digits)
Measurement interval .................................... approx. 2-3 measurements/second
AC measurement method .............................. True RMS, AC-coupled
Test lead length ............................................. approx. 90 cm
Measuring impedance ................................... ≥10 MΩ (400 mV: ≥100 MΩ)
Measuring terminal clearance ....................... 19 mm (COM-V)
Low battery indicator ..................................... Battery voltage <3.6 ±0.2 V
"Dangerous voltage" indicator ....................... ≥30 V/AC-DC
"Range exceeded" alarm ............................... ≥600 V/AC-DC, ≥10 A/AC-DC
"OL" (overload) alarm .................................... ≥610 V/AC-DC, ≥10,10 A/AC-DC or
Automatic power-off ...................................... after approx.15 minutes (can be
Current consumption (auto off) ...................... <50 µA
Operating voltage .......................................... 3 x AAA 1.5 V batteries
Operating conditions ...................................... 0 to +40 °C (<75 % RH)
Operating altitude .......................................... max. 2000 m above sea level
Storage temperature ...................................... -10 °C to +50 °C
Weight ........................................................... approx. 375 g
Dimensions (L x W x H) ................................. 190 x 90 x 43 mm
Measuring category ....................................... CAT III 600 V
Pollution degree ............................................. 2
Operating environment .................................. Indoor use
Safety regulations .......................................... EN 61010-1 and EN61010-2-033
F1 FUSE ........................................................ Φ6.35×32 mm, FF 10 A, H 600 V,
F2 FUSE ........................................................ Φ5×20 mm, FF 2.5 A, H 700V, break-
measurement >4000 counts
manually disabled)
breaking capacity: 10 kA
ing capacity: min. 300 A