Herunterladen Inhalt Inhalt Diese Seite drucken

Wall Mounting Bracket When Replacing An Appliance - STIEBEL ELTRON DHE Touch 18/21/24 Bedienung Und Installation

Vorschau ausblenden Andere Handbücher für DHE Touch 18/21/24:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

INSTALLATION
Installation options
f When installing the connection pipes without offset, break
f
off the sealing lips on the cover guide pieces.
f Click the cover guides into place in the knock-outs.
f
f Position the back panel guide pieces on the pipes. Push them
f
together. Then push the guide pieces against the back panel
as far they will go.
f Secure the lower back panel section with a screw.
f
Note
Use the cover guide pieces with sealing lips if the connec-
tion pipes are slightly offset. In this case, the back panel
guide pieces are not fitted.
13.9 Installation of the lower back panel section in
the case of threaded fittings on finished walls
3
1
1 Lower back panel section
2 Connection piece as delivered
94
|DHE Connect | DHE Touch   
3 Screw
If using threaded connections on finished walls, the lower back
panel section can also be installed after fitting the taps/valves. To
do this, carry out the following steps:
f Cut open the lower section of the back panel.
f
f Fit the lower section of the back panel by bending it out at
f
the sides and guiding it over the pipes.
f Insert the connection pieces into the lower section of the
f
back panel from behind.
f Click the lower section of the back panel into place.
f
f Secure the lower back panel section with a screw.
f
13.10 Wall mounting bracket when replacing an
An existing STIEBEL ELTRON wall mounting bracket may be used
when replacing appliances (except for DHF instantaneous water
heater).
2
f Break through the back panel of the appliance to expose the
f
threaded stud on the fitted wall mounting bracket.
Replacing a DHF instantaneous water heater
appliance
www.stiebel-eltron.com

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis