Herunterladen Inhalt Inhalt Diese Seite drucken

Master And Slave Connection - Lenze 9300 vector Montageanleitung

Vorschau ausblenden Andere Handbücher für 9300 vector:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Show/Hide Bookmarks
4
Electrical installation

Master and slave connection

4.2
Master and slave connection
Installation of the DC busbars
Fig.9-2
62
Mounting of +DC/-DC busbars
Preparations
1.
Remove each cover from the master and slave to access the power sections (Fig.9-2).
Each cover is fastened with 4 screws.
2.
Remove the hexagon socket screws MX in the master and the slave for the +DC
connection.
3.
Remove the hexagon socket screws MX in the master and the slave for the -DC
connection.
Put aside the connecting cable
Install the +DC/-DC busbars (busbars and fixing material are included in the scope of supply)
1.
Position the +DC busbar
2.
Fasten the +DC busbar
M8 × 45 mm
, plain washer
3.
Position the -DC busbar
4.
Insert 2 hexagon socket screws M8 × 45 mm
washers
into the bore holes of the DC busbar
distance sleeves
.
5.
Screw the hexagon socket screws
6.
Lay the connecting cable
busbar
and plain washer
7.
Tighten the hexagon socket screws
for the installation of the -DC busbar.
in the master and the slave.
in the master and the slave with 1 hexagon socket screw
and distance sleeve
. (Tightening torque: 10.9 Nm)
in the master and the slave.
each in the master and slave with plain
finally passing them through the
into the threaded holes in the master and the slave.
in the master and slave with the cable lug between the
(see details).
(tightening torque: 10.9 Nm).
9300VEC024
EDKVF9383 DE/EN/FR 1.0

Werbung

Inhaltsverzeichnis
loading