44 | English
– Check the levelling accuracy after calibration (see "Check-
ing the Levelling Accuracy in the Horizontal Position",
page 42). If the deviation is still outside of the maximum
permitted limit of ±3 mm, have the measuring tool
checked by a Bosch customer service agent.

Y-Axis Calibration

– Mount the measuring tool in the horizontal position on a tri-
pod 63 (accessory).
– Place the tripod 30 m in front of the wall. The Y-axis indica-
tor imprinted on the measuring tool must be pointing per-
pendicular to the wall.
– Switch the measuring tool on.
– Simultaneously press the calibration
button 25 and the slope button 20 for
approx. 2 s.
The symbol for calibrating the Y-axis is
shown on the display.
The out-of-level indicator 37 flashes dur-
ing automatic levelling.
– Wait until the measuring tool is levelled in.
– Use the laser receiver to find the centre line and transfer
the height "Y1" of the centre line onto the wall.
– Turn the measuring tool 180° without adjusting the height
of the tripod.
– Wait until the out-of-level indicator 37 stops flashing and
the measuring tool is levelled in.
– Use the laser receiver to find the centre line and transfer
the new height "Y2" of the centre line onto the wall.
– Determine the exact centre between the centre lines "Y1"
and "Y2" and position the laser receiver on it using the cen-
tre mark 16.
– Press the slope button 18 or 20 until
/
the centre line indicator 43 lights up
continuously. If the audio signal is
switched on, a continuous tone sounds.
– Press the calibration button 25 to save
the calibration.
The symbol for completing calibration is
shown on the display.
– Check the levelling accuracy after calibration (see "Check-
ing the Levelling Accuracy in the Horizontal Position",
page 42). If the deviation is still outside of the maximum
permitted limit of ±3 mm, have the measuring tool
checked by a Bosch customer service agent.

Z-Axis Calibration (GRL 500 HV)

– Mark a vertical line on the wall using a plumb line.
– Mount the measuring tool in the vertical position on a tri-
pod 63 (accessory).
2 610 031 676 | (15.7.14)
– Place the tripod 5–10 m in front of the wall.
– Switch the measuring tool on.
– Simultaneously press the calibration
button 25 and the slope button 18 for
approx. 2 s.
The symbol for calibrating the Z-axis is
shown on the display.
– Align the tripod so that the laser beam crosses the vertical
line on the wall.
The out-of-level indicator 37 flashes dur-
ing automatic levelling.
– Wait until the measuring tool is levelled in.
– Press the slope button 18 or 20 until
/
the laser beam is as parallel as possible
to the vertical line on the wall.
– If you do not achieve congruence, repeat the previous
steps (align tripod, allow measuring tool to level in, align la-
ser beam using slope buttons).
– Press the calibration button 25 to save
the calibration.
The symbol for completing calibration is
shown on the display.
– Check the levelling accuracy after calibration (see "Check-
ing the Levelling Accuracy in the Vertical Position",
page 43). If the deviation is still outside of the maximum
permitted limit of ±1 mm, have the measuring tool
checked by a Bosch customer service agent.

Working Advice

 The measuring tool is equipped with a radio interface.
Local operating restrictions, e.g. in airplanes or hospi-
tals, are to be observed.
 Always use the centre of the laser line for marking. The
width of the laser line changes with the distance.

Setting the Display of the Units

The distance between rotational plane and centre line is
shown on the display in [mm] or [inch: decimals/fractions].
The default setting in the delivery condition is
[mm].
– Simultaneously press the measuring accuracy
setting button 23 and the slope button 20 re-
peatedly until the desired setting is reached.
The setting for the units is saved when the tool is switched off.