Requirements

1.1

Hardware- Requirements

Computer
CP 5412 (A2)
I/O Range
Installationsanleitung CP-5412/Windows NT
C79000-B8274-C375-02
The product CP-5412/Windows NT can only be used on AT-compatible
PCs with an ISA slot.
Please read the README.TXT file on the SIMATIC NET CD.
You require a CP 5412 (A2) SIMATIC NET communications processor
for operation. Before plugging in the CP 5412 (A2) module please set
the DIP switch to the I/O range proposed by the installation program. If
you are installing several modules, make sure that a different I/O
range is set on each CP.
Each CP 5412 (A2) occupies four continuous addresses in the I/O
address area starting at a selectable base address. The following base
addresses (hex) are available:
240, 244, 248, 24C,
280, 284, 288, 28C,
300, 304, 308, 30C,
390, 394, 398, 39C.
How to set the address (with a DIL switch) is described in Chapter 6,
„Appendix - Installation Instructions for the CP 5412 (A2)".
Please make sure that the I/O range you have selected is not used for
any other purpose in your system.
Installation Instructions CP-5412/Windows NT
47